    BlokSeT New Generation Pre Intelligent Low Voltage Complete Equipment
    Rated main circuit current
    Rated current
    The rated voltage
    Application
    1.1 Scope of application

    With its excellent performance experience, high reliability and quality, and comprehensive and leading intelligent power distribution solutions, it has won full recognition from international and domestic users. Its achievements span various fields such as construction, industry, energy, and infrastructure, representing the international advanced level of low-voltage complete equipment.

    1.2 Performance

    ■ Excellent performance experience

    Excellent electrical performance in the industry, meeting various customer needs

    The anti-corrosion and salt spray environment solution meets the stringent environmental requirements on site

    EMC (Electromagnetic Compatibility) performance is excellent, meeting the on-site anti-interference capability requirements

    With a high resistance to arcing up to 690V85kA0.5s and a seismic intensity of 9 degrees, it meets the on-site operation and maintenance safety as well as vibration environmental requirements

    ■ Excellent industry parameters

    Complies with international standards, including IEC61439, IEC60529, and IEC60947

    Comply with local standards, fully meet local regulations and technical requirements

    The system utilizes Schneider Electric switch components to ensure optimal operation

    ■ Strong seismic performance

    The standards are IEC60068-3-3 and GB/T2424.25

    Resistant to earthquake intensity of 9 degrees

    ■ High-level arc protection

    Standards IEC61641-V3, GB/T18859

    Withstands up to 85kA 0.5slpc arc

    ■ Comprehensive anti-corrosion plan

    Standard IEC60721-3-3

    H2S and SO2 gas protection

    Petrochemical, mining, and metallurgical industries
    Technical specification
    Main Technical Parameters Table of BlokSeT's New Generation Pre-Intelligent Low-Voltage Complete Equipment

    DC parameters
    Application: Power distribution/motor control
    IS (Operation and Maintenance Index): 211 to 333
    Reference standards: IEC 60529, IEC61439-1/2, IEC61641, GB/T7251.1/2, GB/T 7251.8, GB/T18859, GB/T2424.25
    Climate tolerance, damp heat resistance: IEC 60068-2-30
    Climate tolerance Dry heat tolerance: IEC 60068-2-2
    Climate tolerance Low temperature tolerance: IEC 60068-2-1
    Climate tolerance, salt spray resistance: IEC 60068-2-11
    Installation locations: Indoor
    Environment: Class 2
    Mechanical data
    Cable entry/exit: top/bottom
    Wiring method: front*/rear
    Protection level: IP20~54
    Isolation form: 1/2b/3a/3b/4b
    Connection form: FFF/WWW
    Size (mm) Height: 2200*
    Dimensions (mm) Width: 400/600/700/800/900/1000/1100/1200/1300/1400/1600
    Size (mm) Depth: 600/1000
    Average weight per unit: 650kg
    Shell: epoxy resin powder coating >50μ
    Shell color: RAL9003/RAL7016
    Electrical data
    Rated insulation voltage (Ui): 1000V
    Rated operating voltage (Ue): 400/690*VAC
    Rated frequency (F): 50/60Hz
    Rated impulse voltage (Uimp): 12kV
    Rated auxiliary circuit voltage: 230VAC max
    Overvoltage level: IV
    Pollution level: 3
    Horizontal busbar rating: up to 7000A
    Rated value of vertical busbar: up to 3200A
    Horizontal busbar Rated short-time withstand current (Icw/1s): 30/50/65/80/100kA
    Horizontal busbar Rated peak withstand current (lpk): 63/105/143/176/220kA
    Rated value of vertical busbar: Rated short-time withstand current (Icw/1s): 30/50/65/70/80kA
    Vertical busbar rating Rated peak withstand current (lpk): 63/105/143/154/176kA
    Internal combustion arc personal protection IEC61641V3: 85kA for 0.5s (Ipc arc), 65kA for 0.3s (lp arc)
    The seismic resistance can reach GB/T2424.25: earthquake intensity of 9 degrees
    Grounding system: TT-IT-TNS-TNC
    Maximum incoming and outgoing line switch: 6300A
    Maximum motor capacity: 250 kW
    Download
    点击下载 附件:BlokSeT新一代预智低压成套设备.pdf    大小: 37.64MB 下载:
    Leave a message
    Under construction...
    Committed to technological innovation
    Make electricity supply more reliable, make electricity use more secure.
    Product quotation consultation
    A free consultation
    hotline:400 8099 777

    CONTACT US

    WeChat

    Jubang science and technology park, wei16 road, leqing economic development zone, zhejiang province

    • phones:+86577 62799786
    • fax:+86577 62799771
    • Email:jubanggroup@163.com
    • web:www.wanlilouti.com
    • Customer service hotline:400 8099 777
    网站地图